Our core range. Mechanical splices from 16 mm to 40 mm, made to Class H of IS 16172:2023 in EN8D steel. We laser-mark every one for full reverse traceability and dispatched with a Material Test Certificate.
We square cut the bar end, cold forge it to enlarge it, then cut a parallel thread. The threaded section is therefore never smaller in area than the parent bar.
We turn the coupler from EN8D round bar, then bore and thread it on CNC. We gauge it with pitch and Go/No-Go gauges that carry third-party calibration certificates. Because the splice is mechanical, its capacity does not depend on bond with the surrounding concrete. The joint survives loss of cover from impact or seismic action.
Joins two bars of the same diameter. This is the everyday splice for columns, walls, rafts, piers and deck slabs. We supply it across the full 16 mm to 40 mm range.
Joins two different bar diameters in one splice. Use it where column steel steps down through a storey, or where a pier reduces above the pile cap. We supply it as ordered combinations.
For bars that cannot be rotated, where one end is already cast in or the cage is fixed. It uses the Type B full-thread arrangement, so the coupler itself travels along the bar.
| Coupler size | OD (mm) | Length (mm) | Pitch (mm) | Thread |
|---|---|---|---|---|
| 16 mm | 30 | 36 | 2.5 | 20 × 2.5 |
| 20 mm | 33.5 / 34 | 40 | 3 | 24 × 3 |
| 25 mm | 42 | 50 | 3.5 | 30 × 3.5 |
| 28 mm | 44 | 56 | 3.5 | 33 × 3.5 |
| 32 mm | 53 | 64 | 4 | 36 × 4 |
| 36 mm | 60 | 72 | 4 | 42 × 4 |
| 40 mm | 63 | 80 | 4 | 45 × 4 |
Reducer couplers are supplied as ordered diameter combinations. Dimensions for reducers and for sizes outside this range are confirmed at enquiry.
*We can manufacture custom sizes on your requirement.
At every size the coupler's cross-sectional area exceeds the bar's, so the splice is never the weak section.
| Coupler size | ID (mm) | OD (mm) | Area of TMT (mm²) | Area of coupler (mm²) | Safe area (mm²) |
|---|---|---|---|---|---|
| 16 mm | 17.5 | 30 | 201.06 | 392 | +191 |
| 20 mm | 21 | 34 | 314.16 | 455 | +141 |
| 25 mm | 26.5 | 42 | 490.87 | 678 | +187 |
| 32 mm | 32 | 53 | 804.25 | 1,187 | +383 |
| 40 mm | 41 | 63 | 1,256 | 1,526 | +270 |
Safe area is the margin of coupler section over parent bar section. The values are nominal and for design guidance. Ask us and we will confirm the figures for your project.
Laser marking, not ink. The marks survive handling, concrete and weather, which is what makes a lot reverse traceable years after the pour.

Spectro and tensile results per diameter, against the heat number, with every dispatch.
Slip, cyclic tensile, low-cycle and high-cycle fatigue reports from NABL-accredited laboratories.
Packed in corrugated boxes with VCI bags, with a verified piece count, and ready stock held across all sizes and reducers.
We can trace the raw material source for every lot, and we issue the supporting reports with it.
Send us the bar diameters, the quantities and the site location. You get a technical offer, a sample Material Test Certificate and a lead time, usually on the same working day.